AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV

China Wuhan GDZX Power Equipment Co., Ltd certification
China Wuhan GDZX Power Equipment Co., Ltd certification
Product is good by performance, yes it is good for xxxxxx market.

—— Mr Dudani

Your product received very good, we will order one more piece

—— JS

You are very nice company. Thanks for your hospitality i spend very informative in your office

—— Yousri

Good for whatever the product or service, you got my trust through this deal.

—— Rahul

Very reliable supplier and partner, solving my question with great patience and perfession.

—— Gaurav

I'm Online Chat Now

AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV

AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV
AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV

Large Image :  AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV

Product Details:
Place of Origin: CHINA
Brand Name: GDZX
Certification: ISO9001
Model Number: ZXBXZ
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Wooden Case
Delivery Time: 5-20 working days
Payment Terms: T/T, L/C, MoneyGram, Western Union
Detailed Product Description
V Distortion: <1.0% Input V: 380V
Q Factor: Q≥30(f=45Hz) Output Wave: Since Wave
F Range: 30Hz~300Hz System Accuracy: 1.5%
High Light:

ac resonant test system

,

resonance test series

1350kVA 270KV AC High Voltage Resonant Test System for 110KV Substation Cables

 

This series devices are designed for AC withstand voltage test of substation primary equipment under 550KV or below, mainly composed of variable-frequency power supply, exciting transformer, reactor and capacitive Voltage divider

 

Features:

 

1. rated voltage:
    27kV--- meets AC withstand voltage test of 10kV cable

                 working frequency 30-300Hz

                 Test voltage is not more than 22kV, test time is 5min;
    54kV--- meets AC withstand voltage test of 35kV cable

                 Working frequency 30-300Hz

                 Test voltage is not more than 52kV, the test time is 60min;

    135kV--- meets AC withstand voltage test of 110kV cable 

                 Working frequency 30-300Hz

                 Test voltage is not more than 128kV, test time is 60 min;

    270kV--- meets AC withstand voltage test of 110kV sbustation 

                  Working frequency 30-300Hz

                  Test voltage is not more than 265kV test time is 1 min;

2. output voltage waveform distortion rate: <1.0%
3. allow continuous working hours: one time working for 60 minutes under rated conditions;
4. Quality factor of the device: Q > 30 
5. device output waveform: sine wave
6. input power supply: 380V or 220V
7. frequency regulation range: 30Hz ~ 300Hz
8. system measurement precision: 1.5%
9. over voltage, over current, zero start and other protection functions.

 

 

COMPOSITION

 

1.  Frequency conversion power supply 1 unit


(1) rated power: 22 kW
(2) Input voltage: three phase 380V 50Hz
(3) output voltage: 0 ~ 400V adjustable
(4) Output voltage frequency: 30 ~ 300Hz
(5) 0.1Hz regulation step
(6) Frequency instability is less than 0.02%
(7) Output current: 0 ~ 55A

 

2. Frequency conversion power supply 1 unit


(1) rated power: 75 kW
(2) Input voltage: three phase 380V 50Hz
(3) output voltage: 0 ~ 400V adjustable
(4) Output voltage frequency: 30 ~ 300Hz
(5) 0.1Hz regulation step
(6) Frequency instability is less than 0.02%
(7) Output current: 0 ~ 187.5A


3.  High voltage reactor (12 units)


(1) rated working voltage: 27kV
(2) rated working current: 4.17A
(3) rated inductance: 32H
(4) Continuous working time: 60min
(5) Temperature rise: less than 65ºc
(6) Working frequency: 30~300Hz


4.  excitation transformer 2 units


(1) rated capacity: 37.5kVA
(2) input voltage: 400V
(3) output voltage: 3/6/18kV
(4) output current: 12.5/6.5/2.08A


5. capacitance divider (1 units)


(1) self capacitance: 1000pF
(2) rated voltage: 270kV
(3) working frequency: 30 ~ 300Hz
(4) uncertainty: 1.5%


6. test line (1 sets)

AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV 0

 

AC High Voltage Resonance Test Series 1.5% System Accuracy Three Phase 380V 50Hz 1350kVA 270KV 1

Contact Details
Wuhan GDZX Power Equipment Co., Ltd

Contact Person: Emma

Tel: 86-17396104357

Fax: 86-27-65526007

Send your inquiry directly to us (0 / 3000)